Installing the SCOPIA Gateway 23
Preparing for Installation
10BaseT or 100BaseT LAN cable
Ambient room temperature range of 41
o
F to 104
o
F (5
o
C to
40
o
C)
Note The hottest ambient temperature supported by RADVISION for the
SCOPIA 1000 platform is 104
o
F (40° C). Any ambient temperature above
104
o
F (40° C) is considered a failure condition. Up to 104
o
F (40° C), the
SCOPIA 1000 platform supports a single feed failure (leaving four power
supplies operational), where the total chassis load (including the fans and
positronic cable losses) does not exceed 1300W.
Non-condensing relative humidity range of 5% to 85% (to 90% for
96 hours)
Note The SCOPIA 1000 platform also supports a severe conditions ambient
temperature above 40° C, up to 55° C, with all eight power supplies
operational, for 96 hours. Storage temperature -40° C to 70° C.