90 SCOPIA 400/1000 Gateway User Guide
Configuring Gateway Settings
In the IP Address field, enter or edit the peer IP address.
Note Two peers cannot have the same IP address or host name/Uniform
Resource Locator (URL).
In the IP Port field, enter or edit the peer IP port number.
In the Description field, enter or edit the description of the peer.
Click Upload.
Note You cannot add a single peer to the Peer list section more than once.
To delete a peer device, select the peer device and click Delete. Deleting
a peer does not cause its active calls to disconnect, but no new calls are
routed to the deleted peer.
Note The peer hunting process stops when one of the peer devices accepts
the call or when the call is rejected with a disconnect reason. When a Gateway
has scanned the Peer list section and still cannot connect a call, the following
rules apply: if at least one of the peers rejected the call due to capacity
overload, the call rejection reason (towards the call originator) is “No
Resources”; in all other cases, the call rejection reason is “Unreachable
Destination.”
7 In the Peer hunting timeout (sec) field, enter the length of time (between
1 and 10 seconds) for which the Gateway waits for a Transmission
Control Protocol (TCP) response from each peer device contacted. The
default value is 5 seconds.
8 Select the Accept calls from defined peers only check box if you want
the Gateway to reject incoming calls from IP-side entities not defined in