Figure 5-6 The Status Map showing the Gatekeeper connection
d. Verify that the MCU is connected to the Ethernet.
e. Verify that the MCU is connected to the Gatekeeper.
Configuring SIP Server Settings
You can configure settings for SIP server profiles which set how the MCU and the registrar interact.
Depending on connection types supported by the SIP server, MCU supports these transport
connection types for sending messages to SIP server:
UDP
TCP
TLS
Procedure
Step 1 Select Configuration .
Step 2 Select Protocols.
Step 3 Select Enable SIP protocol to enable MCU communication with the SIP server.
Step 4 Enter the SIP domain of the MCU in the Default SIP domain field as defined in the SIP server.
An example of a SIP domain is company.com.